Estimate runtime by mission phase
A 24 V, 10 Ah pack has an estimated 240 Wh of nominal energy. An 80% budget allows 192 Wh for the mission.
Account for different loads
Electronics draw 18 W throughout. The drive adds 150 W for 80% of a 20-minute phase, using 46 Wh including electronics. Loading adds 180 W at a 35% duty cycle for five minutes, using 6.75 Wh. Waiting adds 12 W for ten minutes, using 5 Wh.
Read the estimate
The 35-minute mission uses 57.75 Wh and leaves 134.25 Wh within the energy budget. Three full missions fit. The repeating load averages 99 W, so the runtime estimate is about 116 minutes. A real test captures changes in pack voltage, terrain, temperature, and load.
Estimate your mission